TEST DIRECTORY

0 selected

Laboratory:Hachioji

Human chorionic gonadotropin (HCG)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Human chorionic gonadotropin (HCG)
    serum
    0.5
    S09

    A00
    Refrigeration
    2-4 CLEIA

    Chemiluminescent enzyme immunoassay (CLEIA)
    Antibodies linked to the solid phase are reacted with antigens that are secondarily reacted with enzyme-labeled antibodies.
    After adding a chemiluminescent substrate, the emission intensity is measured.

    ≦ 2.7
    (mIU/mL)

COMMENT


Total HCG is measured.
The antibodies recognize HCG-β. This is effective for the diagnosis and prognostic management of trophoblastic disease. It is the method recommended by the 3rd edition of the General Rulesfor Clinical and Pathological Management of Trophoblastic Diseases, with the measurement sensitivity of 1.0 mIU/mL.