TEST DIRECTORY

0 selected

Laboratory:Hachioji

Collagen type I, C-terminal telopeptide (ICTP)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Collagen type I, C-terminal telopeptide (ICTP)
    serum
    0.3
    S09

    A00
    Refrigeration
    2-4 RIA2 antibody assay

    Radio immunoassay (RIA)
    A target antigen is labeled with radioactive isotope (RI) and bound to its specific antibodies which is then competitively reacted with an antigen in a specimen. After the antigen-antibody reaction, the bound labeled antigens (bound) are separated from the unbound ones (free), and the antigen concentration is determined based on the proportion of radioactivity.
     To separate the bound and free antigens (B/F separation), the following methods are used. Solid-phase method:Antibodies are linked to the solid phase. Double antibody method: Antigen-antibody complexes are bound to the second antibody and precipitated. Ammonium sulfate precipitation method: Antigen-antibody complexes are precipitated by ammonium sulfate. PEG method: Antigenantibody complexes are precipitated by a precipitation reagent.

    < 4.5(ng/mL)

CONTAINER

Related test

Notifications of URL changes/lab information added

ラボを選択してください

Choose a laboratory

Notifications of URL changes/lab information added

Laboratory List