Laboratory:Hachioji
- TOP
- haematological test
- standard haematology, hemogram
- Peripheral blood general test
Laboratory:Hachioji
○Peripheral blood general test
CODE:0B03 6
-
TEST NAME
SPECIMEN
REQUIREMENT
(mL) CONTAINER CAP COLOR STORE
TEMPERATURE
(STABILITY) TURNAROUND
TIME (DAY) METHODOLOGY REFERENCE RANGE
(UNIT) -
Peripheral blood general test
Blood (EDTA-2K added)
2.0
PK2
2-4 automatic mechanical method White blood cell count (WBC)
M3900-9800
F3500-9100
(/μL)
Red blood cell count (RBC)
M427-570
F376-500
(×104/μL)
Hemoglobin content (Hb)
M13.5-17.6
F11.3-15.2
(g/dL)
Hematocrit(HT)
M39.8-51.8
F33.4-44.9
(%)
MCV
M82.7-101.6
F79.0-100.0
(fL)
MCH
M28.0-34.6
F26.3-34.3
(pg)
MCHC
M31.6-36.6
F30.7-36.6
(%)
Platelet count
M13.1-36.2
F13.0-36.9
(×104< /sup>/μL)
COMMENT
Avoid freezing. Acceptable days are Monday through Friday. However, acceptances cannot be made on the day before public holidays. Please submit the specimen on the same day after blood collection.
If testing blood 12 hours or more after collection, test results may not be reported due to cellular degeneration. Hemolysed, coagulated and frozen specimens cannot be measured.
Collect blood in the container shown below, mix well, and preserve refrigerated.
Hemolysed, coagulated and frozen specimens cannot be measured.
Submit the specimen on the same day after collection.
CONTAINER
PK2 旧容器記号 g H1 3
EDTAー2K入り (真空採血量2mL)
内容:EDTAー2K 3.8mg
貯蔵方法:室温
有効期間:製造から2年