TEST DIRECTORY

0 selected

Laboratory:Hachioji

TSH receptor antibody (quaTSH receptor antibody (quantitative)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • TSH receptor antibody (quaTSH receptor antibody (quantitative)
    Serum
    0.4
    S09

    A00
    Refrigeration
    2-5 RRA

    RRA (Radio receptor assay)
    Radio receptor assay
    The measurement principle is the same as RIA, a method that uses a receptor instead of an antibody and determines biological activity from its reactivity.

    Less than 1.0 (IU/L)

COMMENT


Human type receptors are used. It is a second-generation TRAb using solid phase method.
(About standard values) As a small number of healthy people may show results exceeding 1.0 IU/L, it is recommended to set a gray area at 1.0 to 1.5 IU/L in Europe and America.